i-data Electronic Documentation
ida FS 250 /
ida FS 250 PDS
Operator’s Guide
Doc. no D60256 Revision 03
WARNING:
This equipment generates, uses, and can radiate radio frequency energy and if not installed and used
in accordance with the instruction manual, may cause interference to radio communications. It has
been tested and found to comply with the limits for a Class A computing device pursuant to Subpart
B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such inter-
ference when operated in a commercial environment. Operation of this equipment in a residential
area is likely to cause interference in which case the user at his own expense will be required to take
whatever measures may be required to correct the interference.
EMC directive:
This product observes the rules and regulations of the EMC directive. If so required, a declaration of
conformity in local language stipulating the applied rules and regulations can be obtained.
Trademarks:
Company and product names mentioned in this datasheet are trademarks or registered trademarks of
their respective owners. i-data international a-s cannot be held responsible for any technical or
typographical errors and reserves the right to make changes to products and documentation without
prior notification.
The i-data Printing Solutions
Page view 0
1 2 3 4 5 6 ... 55 56

Summary of Contents

Page 1 - The i-data Printing Solutions

i-data Electronic Documentationida FS 250 /ida FS 250 PDSOperator’s GuideDoc. no D60256 Revision 03WARNING:This equipment generates, uses, and can rad

Page 2 - About i-data

Connecting to Systemida FS 250, Operator's Guide-10-2. Installation RequirementsBefore connecting the ida FS 250, you should check the requiremen

Page 3 - Related Manuals

Connecting to Systemida FS 250, Operator's Guide-11-&&??%(defines % as temporary ESC character)%Y8,<number of new language>%(select

Page 4 - Table of Contents

Connecting to Systemida FS 250, Operator's Guide-12-3. Installation and Connections of theida FS 250This chapter starts with an overview of the f

Page 5

Connecting to Systemida FS 250, Operator's Guide-13-For this connection you need a spare cable ending in a 25-pole RS connector(i-data order no.

Page 6

Connecting to Systemida FS 250, Operator's Guide-14-3.2 EmulationAs a default the ida FS 250 will emulate IBM 3812/5219/3816.The ida FS 250 PDS e

Page 7 - Kit Contents

Connecting to Systemida FS 250, Operator's Guide-15-Non-IPDSSelection Emulation*0 3812 / 5219 / 3816 1 5224 2 5225 3 5256 4 4234 5 3812/5219/3816

Page 8 - 1. Introduction to ida FS 250

Connecting to Systemida FS 250, Operator's Guide-16-Y37,n1Write Emulation3812 *3812 / 5219 / 38165224 52245225 52255256 52564234 4234 * default

Page 9 - 1.3 Supported Control Units

Connecting to Systemida FS 250, Operator's Guide-17-3.4 Connecting the ida FS 250 to the PrinterCAUTION:All connections to the ida FS 250 protoco

Page 10 - 2. Installation Requirements

Connecting to Systemida FS 250, Operator's Guide-18-3.4.2 Connecting via RS-232 outputNote: This does not apply for the ida FS 250 PDS1. To use t

Page 11 - 2.2.2 Paper Size (EU/US)

Connecting to Systemida FS 250, Operator's Guide-19-If the printout format does not match the test printout in Appendix B. or ifnothing was prin

Page 12 - 3.1 The Rear Panel

ida FS 250, Operator's Guide-2-Document No.: D60256-03©Copyright i-data international a-s 1997i-data international a-sVadstrupvej 35-43DK-2880 B

Page 13

Connecting to Systemida FS 250, Operator's Guide-20-If all three (a. b. and c.) are in order, contact your systems support personnelor your point

Page 14 - 3.2 Emulation

Connecting to Systemida FS 250, Operator's Guide-21-3.5.2 TimeoutThe ida FS 250 enables printer sharing between the system and a PC. Forthis purp

Page 15 - 3.2.2 Via the Line

Specifying Share Timeout and Stringida FS 250, Operator's Guide-22-4. Operation of ida FS 250 The ida FS 250 top panel has been designed to re

Page 16 - 3.3 Upgrading to IPDS

Specifying Share Timeout and Stringida FS 250, Operator's Guide-23-SER (Serial input/output)The indicator LED has 3 statesState IndicationONIndic

Page 17 - Connecting to System

Specifying Share Timeout and Stringida FS 250, Operator's Guide-24-5. Specifying Share Timeout and StringIn order to specify the timeout for a sp

Page 18

Specifying Share Timeout and Stringida FS 250, Operator's Guide-25-%X1NOTE: %X1 will delete the temporary escape character.The FSL string above w

Page 19

IPDS Setupida FS 250 PDS, Operator's Guide-26-6. idaSetup - IPDS ProgrammingNOTE:This chapter only applies to the converter whenmounted with an I

Page 20 - Test via the address switch

Programmingida FS 250, Operator's Guide-27-7. IRQ HandlingThis section describes how to recover from various IRQ conditions.• Paper jam• Out-of p

Page 21 - 3.5.2 Timeout

Programming via Shareportida FS 250, Operator's Guide-28-8. Programming ida FS 250 - non-IPDSThe ida FS 250 works using a large number of interna

Page 22 - 4.1 ida FS 250 top panel

Programming via Shareportida FS 250, Operator's Guide-29-8.2 Defining a Temporary Escape CharacterThe ESC Character may be defined as a tem

Page 23 - READY (Printer Ready)

Table of Contentsida FS 250, Operator's Guide-3-PrefaceSeptember 1997This manual applies to the ida FS 250 and the ida FS 250 PDS protocolconvert

Page 24

Programming via Shareportida FS 250, Operator's Guide-30-8.5 Setup Functions supported (PCL Mode)No. DescriptionY2 LPIY3 CPIY8 LU1 LanguageY10 Pa

Page 25

Programming via Shareportida FS 250, Operator's Guide-31-No. DescriptionX Save/Overwrite SettingsX1 Store Settings in Permanent MemoryX3 Restore

Page 26 - IPDS Setup

Programming via Shareportida FS 250, Operator's Guide-32-8.6 Quick Reference Guide of Supported FSL FunctionsIn this section the supported FSL

Page 27 - 7. IRQ Handling

Programming via Shareportida FS 250, Operator's Guide-33-No. Name Syntax Parameters2LPI%Y2,<n1>% 3 = 3 LPI 4 = 4 LPI*6 = 6 LPI 8 = 8 LPI3CP

Page 28 - 8.1 The Escape Character

Programming via Shareportida FS 250, Operator's Guide-34-No. Name Syntax Parameters10Page Format%Y10,<n1>[,n2]%n1 0 = Portrait 1 = Landscap

Page 29 - 8.4 Invalid Escape Character

Programming via Shareportida FS 250, Operator's Guide-35-No. Name Syntax Parameters12Paper Size%Y12,<n1>[,n2,n3]%NOTE:Factorydefault depend

Page 30 - Programming via Shareport

Programming via Shareportida FS 250, Operator's Guide-36-No. Name Syntax Parameters15Baud Rate forRS232 inter-face%Y15,<n1>%n1 0 = 300 baud

Page 31

Programming via Shareportida FS 250, Operator's Guide-37-No. Name Syntax Parameters36Suppress IBMcontrol codes%Y36<n1>%*0 = Respect codes 1

Page 32

Programming via Shareportida FS 250, Operator's Guide-38-No. Name Syntax Parameters51User-DefinedString(s) atPower-Up%Y51,<n1>%0-7 = One or

Page 33 - No. Name Syntax Parameters

Programming via Shareportida FS 250, Operator's Guide-39-No. Name Syntax Parameters73Select Trans-late Table%Y73,<n1>[,n2]%----------------

Page 34

Table of Contentsida FS 250, Operator's Guide-4-As the ida FS 250 emulates the IBM 3812 printer in IBM 5219 emulation, usefulinformation may be o

Page 35

Programming via Shareportida FS 250, Operator's Guide-40-No. Name Syntax Parameters88PhysicalMargins%Y88,<n1>,<n2>[,n3]%n10 - +/-3200

Page 36

Programming via Shareportida FS 250, Operator's Guide-41-No. Name Syntax Parameters91Font Defini-tionSee AppendixD. for moredetails onfonts%Y90,&

Page 37

Programming via Shareportida FS 250, Operator's Guide-42-No. Name Syntax Parameters94Font TypefaceDefinitionString%Y93,<n1>,<n2>%n110

Page 38

Programming via Shareportida FS 250, Operator's Guide-43-No. Name Syntax Parameters119Auto-Configuration select%Y119,<n1>%n1*0 = Disable Au

Page 39

Programming via Shareportida FS 250, Operator's Guide-44-9. Programming via ShareportIn order to ease customization of the ida FS 250, FSL param

Page 40

Programming via Shareportida FS 250, Operator's Guide-45-If you have defined % as Escape Character, you activate the engi neeringfunction by typi

Page 41

Error Messagesida FS 250, Operator's Guide-46-10. Errors and RecoveryPrinter-related error messages will be displayed on the printer front panel.

Page 42

Appendix Sectionida FS 250, Operator's Guide-47-Appendix A: Use of ida FS 250 Serial PortThe following connections are available in the serial pl

Page 43

Appendix Sectionida FS 250, Operator's Guide-48-Appendix B: Test Printoutida FS 250Firmware version: S20 140.010/00970005i-data international a-s

Page 44 - 9. Programming via Shareport

Appendix Sectionida FS 250, Operator's Guide-49-Appendix C: Default GFID TableThe factory default GFID Table below lists all the predefined fonts

Page 45 - 9.1 Updating firmware

Table of Contentsida FS 250, Operator's Guide-5-Table of ContentsPreface...

Page 46 - 10. Errors and Recovery

Appendix Sectionida FS 250, Operator's Guide-50-In the table below, an asterisk (*) after the GFID number denotes a simulatedIBM GFID.GFID Font T

Page 47 - Appendix Section

Appendix Sectionida FS 250, Operator's Guide-51-Scalable FontsNOTE:Only applies to printers running PCL Level 5.The ida FS 250 allows GFID access

Page 48 - Appendix B: Test Printout

Appendix Sectionida FS 250, Operator's Guide-52-%Y96,4815%This is 48 point, Helvetica Compressed, bold upright%Y96,1301%This is 13 point, Times R

Page 49

Appendix Sectionida FS 250, Operator's Guide-53-Appendix D: i-data Product PlatformCoax S/370 - 390 SCSida LS 170 External For Centronics attache

Page 50 - IBM GFID

Appendix Sectionida FS 250, Operator's Guide-54-Token Ring S/370 - 390 AFPida PS 03 TR External For Centronics attached laser and matrix printers

Page 51 - Scalable Fonts

Indexida FS 250, Operator's Guide-55-Index—C—ConnectionsA/B Switch, 13Address Switch, 13Parallel In, 12Parallel Out, 12Serial Port (Out), 47Seril

Page 52 - Font examples

Reader's Commentsida FS 250, Operator's Guide-56-READER'S COMMENTSThis manual is part of a library that serves as a reference source fo

Page 53

Table of Contentsida FS 250, Operator's Guide-6-8.6 Quick Reference Guide of Supported FSL Functions ... 329. Progra

Page 54

Kit Contentsida FS 250, Operator's Guide-7-Kit ContentsPlease check that your kit is complete with the following:ida FS 250• ida FS 250 converte

Page 55

Introductionida FS 250, Operator's Guide-8-1. Introduction to ida FS 250This chapter gives a short description of the ida FS 250 converter1.1 In

Page 56 - READER'S COMMENTS

Introductionida FS 250, Operator's Guide-9-• Support of Automatic Page OrientationIPDS:IPDS support - IBM 4028 and 3812 or 3816 emulation.• Non-